BARGAIN SECTION

Ex-Demo Offers
Latest Bargains
Special Offers

GO TO

Car Valeting
Global News
Industry Overview
Products
Quick Link

PRO RANGE STOCK ITEMS

60Hz Cold Pressure Wash
60Hz Hot Pressure Wash
60Hz Vacuums
Chemical Sprayers
Cold Water Pressure Washers
Commercial Vacuum Cleaners
Consumer
Engine Driven Pressure Wash
Hot Water Pressure Washers
Industrial Vacuums
Powered Sweepers
Scrubber Driers
Single Disc Rotary
Steam Generators
Systems XD

PRODUCTS & BUILT TO ORDER

Pressure washers
Vacuum cleaners
Carpet Cleaning
Scrubber dryers
Sweeping machines
Vapour steamers
Water recycling
Product Overview
Engine with Chalwyn Valve
Litter Collectors
Polishing Machines
Under Chassis Wash

TRAILER & SKID MOUNTED

Graffiti & Gum Removal
Mobile High Pressure
Past Projects & Examples
Special Build Sitemaster
Trailer & skid mounted
Wheelie Bin Washers

ULTRA HIGH PRESSURE

Electric & Engine Driven

VEHICLE WASH

Drive through systems

ABOUT US

Company Profile
Contact Us
ISO
Morclean News
Partner links
Price & Delivery
Testimonials

FIXED INSTALLATIONS

Heated Systems
Multi Pump Systems
Multipump Pro Centralized

INNOVATION

CleanGuide
Inflatables & Covers
Separators & Interceptors
Vacuum History
Vacuum Projects
Water Projects
Water Tanks

TECHNICAL & SUPPORT

Download Literature
Faq's & How To
ATEX Directive
Customer Service
Guidelines & Regs
Health & Safety
Instructions & Spec
Online COSHH & Data
Price Lists

SPEEDY RAMP

Buy a Ramp
Will it Fit?

TOOLS

Sitemap






Gas
internal design is easy to service
Click on image to enlarge
The Morclean stationery, hot water gas fired unit has the following options:

  • Control Electronics
  • Chemical solenoid valve
  • 24V remote control
  • 10mtr hose pistol & lance
The features of the tank are:

  • The pump has four diamond-ground all ceramic pistons which are designed for a long service life

  • The break tank is a plastic tank with float valve, which complies with water authority regulations

  • The unit is housed in a heavy steel frame fitted with anti-vibration mountings and enclosed with powder coated sheet steel panelling

  • Automatic standby so when the trigger of the spray gun is pressed, the full power is immediately available. During breaks in work the machine switches to standby mode. This prevents the machine from running in bypass thereby dramatically increasing the life of the pump components

  • The patented regulation safety block retains the working pressure at the lance but allows the pump to start under no load conditions

  • Ultimate over-pressure protection is achieved by an additional safety valve in series with the control safety block

  • The system is equipped with an electric controller and remote-control unit that allows the selection of the following functions with illuminated buttons

    • Start/Stop
    • Foam/Rinse
    • Hot/Cold
All SOLAR Boosters come equipped with stainless steel frames and cabinets
Click on image to enlarge
Electronically detected faults are indicated with the red fault lamp on the control panel and the flashing ìSTOPî button on the remote control unit.

The pumping system will require a flue combustion air

General requirements you need for installation, others may be required depending on site

Electricity - A local 3 phase isolator should be provided to within 1 metre of the pumping system location. It should be capable of supplying 400 volts, 3 phase neutral and earth (5 wire) with a loading of 5.7 Kw protected by a 16 amp slow blowing fuse or MCB.

Water - Low pressure main or feed from storage tank capable of providing at least 960 litres per hour at a maximum temperature of 30?C.
Minimum feed pressure: 2.5 bar
Maximum feed pressure: 10 bar
Terminating in a 3/4 inch BSP isolating valve at the pump unit, which should incorporate a 3/4" hose tail to take a 3/4" I.D flexible inlet hose..

Gas - A neutral gas supply capable of supplying a minimum of 7 cubic metres per hour, for connection to the burner gas inlet connection point which has a ?" BSP isolation valve. The gas connection should be made via a flexible pipe to allow for machine vibration.

Ventilation - Fresh air ventilation from an outside source capable of suppling 82 cubic metres per hour or free air. This means that vents must be provided of 608 CM2 at low level and 304cm2 at high level in the room where the pumping system is to be located.


Technical SpecificationMORCLEAN SOLAR BOOSTER 7-57GMORCLEAN SOLAR BOOSTER 7-51GHMORCLEAN SOLAR BOOSTER 5-35G
Pressure bar160150125
Pressure MPa161512.5
Water Flow - Qmax l/h12001100835
Water Flow -QIEC l/h1110 1030 780
Cleaning Impact kg/force5.75.13.5
Noise level dBa777676
Max inlet temp oC308530
Power Absorbed KW7.67.16.2
Voltage/phase/frequency/current V/~Hz/A400/3/50/15.5400/3/50/14.5400/3/50/13
Heating Capacity KW907080
Naturalgas consumption (gas, 10.35 kwh/m39.37.38.3
Dimensions L x W x H mm690 x 860 x 1250690 x 860 x 1250690 x 860 x 1250
Weight kg235220225