the pump features a pressurised sealed oil chamberThe control system is adaptableremote control and computer monitoring is available if requiredColour coded lances ensure the correct volume and pressure

Morclean's Multi Pump is a multi pressure unit containing 2, 3, 4, 5 or 6 heavy duty axial pumps using long life ceramic pistons and stainless steel valves. The pump has a pressurised sealed oil chamber to virtually eliminate oil waste.
Technical Specifications2 pumps3 pumps4 pumps5 pumps6 pumps
Max. water output       l/h20403060408051006120
Current                    A421) 232)
213) 214)
621) 352)
323) 324)
831) 472)
423) 424)
1041) 582)
533) 534)
1251) 702)
643) 644)
Weight                    kg 250300350400450

1)3 x 230 V, 50 Hz 2)3 x 400 V, 50 Hz 3)3 x 440 V, 60 Hz 4)3 x 415 V, 50 Hz

compact, space saving designFor a long and effective working life, the cabinet, water tank, frame and the water passage are constructed from highly durable stainless steel and other non-corrosive materials. The water tank has individual hot and cold water feed which provides mixing in tank to enable automatic selection of desired water temperature with high and low level control,

The tank design incorporates an ‘A’ type air gap and carries WRC approval (No 9712051).

The controls are automatic start and stop which means pumps will stop 25 seconds after use to avoid rapid start stop effect on motors. To ensure equal use of all units the first pump to come on will be the first pump to go off line.
the large access door can be opened left to right or right to leftThe main features to the Multi Pump system are:

  • In the event of a major pipework failure the machine will automatically shut down

  • If necessary individual pumps can be isolated without affecting the remainder of the pumps in the system

  • Display indicating individual pump running hours

  • Diagnostic display indicating: tank levels, pumps in use, thermal overloads, valve conditions, flow path, pressure switch condition


There are 2 requirements to be supplied by the customer. Water and Electricity.

1] The water tank is fitted with two water inlets this allows the user to control the temperature of the water being used for cleaning purposes. one for cold water (marked blue) and one for hot water (marked red). If no temperature control is required both water inlets may be connected to the cold supply pipework. At least one cold water supply should always be connected and the hot water supply should never exceed 80ºC.

Each supply pipe should be able to supply the system with a water volume that exceeds the capacity of the system and be terminated with a 1” BSP isolating valve. These supplies should be installed to within one metre of the connection points on the system. We would recommend he installation of an in-line filter before the pumps if the water supply were likely to contain particulate

2] A power supply cable is required this cable would be four-core cable to provide three phases and earth,

The cable needs to be capable of supplying:
41 amps for 2 pumps
52 amps for 3 pumps
63 amps for 4 pumps
74 amps for 5 pumps
85 amps for 6 pumps.

The Multi Pump requires single-phase electrical supply terminating in a 13 amp 3-pin socket located adjacent to the Multi Pump site to facilitate servicing of the system.


Leasing
Have you considered Leasing?
Do you want to improve your cash flow and make budgeting easy?
Are you aware of the tax savings available?
Click here to find out more about leasing opportunities for Morclean customers.


T: Freephone 0800 1300 402 Email: Click Here

Latest News
 

Newsletter
Please enter your email address below to receive our newsletter emails


All content Copyright © Morclean Ltd 2008